back to list

Am Plessfelde, Hannover

Description

This detached single-family house on a narrow plot of land is planned as a two-story passive house with garage cultivation. The construction is a steel frame with reinforced concrete ceilings and wooden construction in front. The facade consists of plastered wood fiber boards and a ventilated wooden construction for the floor.

Involved parties

Client:

private

Design:

RAUMPLAN - architects Stefanie v. Heeren, Carmen Kiehl

Quality management:

Büro für Bauphysik - Dipl. Ing. architect Stefan Horschler

Building data

Building type:

Detached single-family home

Location:

Hanover

Year of construction:

2010

Residential units:

1

Heated usable space:

177 m2

Subsidies:

BAfA, KfW, proKlima

Building shell

EXTERIOR WALL:

supporting framework:

The steel frame construction provides a flexible floor plan.reinforced concrete ceilings form thermal storage mass.

exterior facade:

The front structure consists of planked wood profiles and is filled with a total of 38 cm cellulose insulation. The building is outside clad with wood fiber boards as plaster base and a wood fiber board with ventilated wood cladding. Inside a gypsum board is mounted on a wooden framework. This space acts as installation level.

HTC = 0.10 W / (m2K)

WINDOWS:

Passive house windows with heat insulating 3-pane glazing in wood and aluminum frame

Outdoor blinds as sun protection

HTC = 0.65 W / (m2K)

ROOF:

Reinforced concrete roof with a slope insulation of polystyrene

HTC = 0.11 W / (m2K)

BASEMENT CEILING:

10 cm polystrene insulation underneath the basement ceiling and 22 cm upon it

HTC = 0,10 W/(m2K)

Building technology

VENTILATION:

central comfort ventilation system with heat- and humidity-recovery functions

heat provision level of 93 %

Installation of ventilation ducts in the concrete ceilings

HEATING:

condensing gas boiler

Heat distribution via panel radiators

Solar thermal system with vacuum tube collectors, 45 ° mounting angle on flat roof for water heating

AIR CONDITIONING:

no active air conditioning installed

Measured values

AIRTIGHTNESS:

n50 = 0,45 h-1

Calculated values

Calculated method: Passivhaus planning package

HEATING ENERGY NEEDS:

13 kWh/(m2a)

????:

85 kWh/(m2a)

????:

29 kWh/(m2a)