back to list

Irma-Pickert-Weg, Hannover

Description

Step by step, CAL-Classic-Haus has risen to the challenges which ever-changing legal standards for insulation and energy savings have presented over the past few years, and developed a building concept which exceeds the strict specifications set by the Passivhaus Institute in Darmstadt. This process includes not only adapting construction methods and carefully integrating materials, but also maintaining a qualified staff. The well-trained team knows their craft otherwise they would not be able to position the first wall of a two-story building and invite people to its topping out ceremony on the very same day. Walls and roofs are pre-finished in the company's own manufacturing facilities under strict quality control supervision. Even though they are only 47 cm thick, the multi-layered wall constructions achieve optimum heat insulation values and, together with the service cavity, create ideal conditions for an airtight building shell. An air heat pump with integrated 200-liter storage units, a heat exchanger, and integrated solar energy components combine to form an efficient and compact heating, hot water, and ventilation device.

Parties involved

Client:

CAL-Classic-Haus

Design:

js-architektur

Building data

Building type:

Single-family home

Location:

Hannover-Wettbergen

Year of construction:

2011-2012

Heated usable space:

181 m²

Subsidies:

KfW, proKlima

Building shell

Exterior walls:

premade wood-panel elements with service cavity plus 36 cm total mineral fiber insulation and breathable wood fiber panels; HTC = 0.09 W/(m2K)

Heat bridging-free connector details were developed for sockets, ceiling connections, eaves, and gableboards.

Windows:

Plastic windows with heat-insulating triple glazing; HTC = 0.76 W/(m2K) including installation related heat bridging

Roof:

premade wooden panel elements with 40 cm total cellulose insulation; breathable exterior wooden softboard panels; HTC = 0.09 W/(m2K)

Floor Plate:

16 cm polyurethane insulation on floor plate, covered by screed with floorboard heating; HTC = 0.14 W/(m2K)

Summertime heat protection:

exterior sun protectors

Building technology

Heating and Ventilation:

Compact heat pump device consisting of an air/water heat pump for heat and hot water with integrated storage unit and integrated heat pump; 6.8 m2 solar heating system

Air conditioning:

Nighttime ventilation via windows in summer

Calculated values

Calculated method: Passivhaus planning package

HEATING ENERGY NEEDS:

15 kWh/(m2a)

TOTAL ENERGY NEEDS FOR HEATING,AIR CONDITIONING,DHW,ELECTRICITY:

Electricity

28 kWh/(m2a)

PRIMARY ENERGY NEEDS FOR HEATING,AIR CONDITIONING,DHW,ELECTRICITY:

72 kWh/(m2a)

CO2 EMISSIONS FOR HEATING,AIR CONDITIONING,DHW,ELECTRICITY:

17 kg/(m2a)